A unique feature of the BattenLok HS® panel is a vertical leg side joint that
is mechanically seamed with an electric seamer for a
weathertight finish. This panel features concealed clips and easy to handle 16" or 12" wide panels custom cut to the desired length.
BattenLok HS® HS can be installed directly over purlins or bar joists. It does not require a solid substructure for support. This roof
system has several different UL® 90 construction numbers.
Gauge
24 gauge (standard)
22 gauge
Length
Maximum 50' (standard), other lengths are available as special requests
Dimensions
16" wide and 2" high (standard)
12" also available
Finish
Galvalume Plus®
Signature® 200 Colors
Signature® 300 Colors
Limitations
Recommended for roof slopes of ½:12 or greater. Oil canning is not a reason
for rejection.
Fasteners
A choice of concealed fastening clips is available for this panel system including UL® rated clips. These clips hold the panel firmly in place without unsightly exposed fasteners. Each clip system offers the ability to accommodate thermal movement.
Usage
This panel is a structural panel that spans up to five feet on purlins, or can be used as an architectural panel over solid deck. This flat panel is designed with striations as an option to minimize oil-canning. It is designed to meet the ever-changing specifications and other industry codes.
Attributes
Factory applied mastic inside of female leg of panel is standard
Swaged end laps
Heavier gauges, striation and embossing (optional)
Roof runs without end lap panels may be erected from either direction
Roof to wall transition
80% less exposed fasteners than traditional side lap panels and all-fasteners are long life
The side lap has been tested for air infiltration and water penetration under ASTM E283 and E331 methods
Vertical Leg
Insulated with thermal blocks
High or low floating clips available
High or low fixed clips available
Panel available in Signature® 300 and Signature® 200 Colors
UL® 90
Panel has striations
Advantages
Insures watertightness and
easier erection
Improves erection and
enhances watertightness
Minimizes oil canning
Flexible and convenient erection
Creates a trimless eave
Increases weathertightness and improves appearance
Minimizes air infiltration and water penetration and enhances acceptability among specifiers
Better transition to hip, valleys, and
roof openings
High energy efficiency system
Allows roof to expand and contract maximizing weathertightness
Provides of varying insulation thickness
25 year finish warranty
Reduces insurance costs
Helps with oil canning
BattenLok HS® Panel 16" - Section Properties
NEGATIVE BENDING
POSITIVE BENDING
Panel
Gauge
FY
(KSI)
WEIGHT
(PSF)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
24
50
1.29
0.0644
0.0578
1.7294
0.1517
0.0926
2.7736
22
50
1.65
0.0902
0.0932
2.4923
0.2033
0.1248
3.7370
Properties Notes:
All calculations for the properties of
BattenLok HS® panels are calculated in accordance with the 2001 edition of the
North American Specification For Design Of Cold-Formed Steel Structural Members.
Ixe is for deflection determination.
Sxe is for bending.
Maxo is allowable bending moment.
All values are for one foot of panel width.
Allowable Uniform Loads
In Pounds Per Square Foot - 16" Panels
24 Gauge (Fy = 50 Ksi)
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5
3.0
3.5
4.0
4.5
5.0
5.5
SINGlE
LIVE
162.0
135.0
115.7
101.3
90.0
74.0
61.1
2-SPAN
LIVE
162.0
128.1
94.1
72.1
56.9
46.1
38.1
3-SPAN
LIVE
162.0
135.0
115.7
90.1
71.2
57.6
47.6
4-SPAN
LIVE
162.0
135.0
109.8
84.1
66.5
53.8
44.5
22 Gauge (Fy = 50 Ksi )
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5
3.0
3.5
4.0
4.5
5.0
5.5
SINGlE
LIVE
233.4
194.5
166.7
145.9
123.0
99.7
82.4
2-SPAN
LIVE
233.4
184.6
135.6
103.8
82.1
66.5
54.9
3-SPAN
LIVE
233.4
194.5
166.7
129.8
102.6
83.1
68.7
4-SPAN
LIVE
233.4
194.5
158.3
121.2
95.8
77.6
64.1
Note: For 12" panel information please contact Star.
Allowable Uniform Loads Notes:
Allowable loads are based on uniform span lengths and Fy = 50 ksi.
LIVE LOAD is limited by bending, shear, combined shear and bending and web crippling.
Allowable loads consider a maximum deflection ratio of L/180.
The weight of the panel has not been deducted from the allowable loads.
THE ALLOWABLE UNIFORM LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.
Please contact manufacturer or manufacturer's website for most current allowable wind uplift loads.
The use of any field seaming machine other than that provided by the manufacturer may damage the panels,
void all warranties and will void all engineering data.
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data,
it is recommended that the design professional have a copy of the most current version of the North American Specification
for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design.
This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer
should reference the most current building code applicable to the project jobsite in order to determine environmental loads.
If fur ther information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.
EFFECTIVE NOVEMBER 3, 2004
SUBJECT TO CHANGE WITHOUT NOTICE
BattenLok HS® is a registered trademark of the NCI Group. Galvalume Plus® is a registered trademark of BIEC International, Inc. Signature® is a registered trademark of the NCI Group.
We recognize that you are looking for more than skill and experience. You want to work with people who value you – before, during and after the sale. Our promise to you is that we will always put you first, and fight hard to exceed your expectations every time! Providing top quality materials and buildings at an ultra-competitive price is where it starts with Apex Metal Building Systems. We have partnered with the most highly regarded manufacturers in the steel building industry to ensure we can provide you with a great bottom-line pricing for a building that will hold its long-term value, providing our customers with a high return on investment.